Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorYilmaz, Deniz
dc.contributor.authorYilmaz, Baris
dc.contributor.authorMancuhan, Ebru
dc.date.accessioned2023-01-10T12:00:24Z
dc.date.available2023-01-10T12:00:24Z
dc.date.issued2020en_US
dc.identifier.citationYilmaz, D., Yilmaz, B., & Mancuhan, E. (2019). The performance evaluation of R744 transcritical ejector and R290/R744 cascade refrigeration systems for Turkey. Thermal Science, 23(6 Part B), 4031-4041.en_US
dc.identifier.urihttps.//doi.org/10.2298/TSCI180911348Y
dc.identifier.urihttps://hdl.handle.net/20.500.12294/3154
dc.description.abstractIn this study, performance of two different environmentally friendly systems with natural refrigerant solutions, R744 transcritical booster system with ejector and a R290/R744 cascade system are examined theoretically by using engineering equation solver software. Operating conditions are determined to represent different climatic regions in Turkey using summer dry bulb temperatures of various cities. The transcritical and the cascade system are assumed to operate at two different evaporation temperatures of -10 degrees C and -32 degrees C. The overall energy efficiency ratio values for each system with respect to the same ambient and evaporation conditions are compared and evaluated. Finally, performance of both systems has been compared and the appropriate solution for each city has been suggested. For cold and mild climate regions of Turkey, the performance of transcritical alternative is found better than the proposed cascade system. Moreover, the performance of transcritical system is observed slightly lower than those of the cascade system in hot climate regions of Turkey such as Aegean, Mediterranean, and South-East Anatolian regions. It is also found that the performance of the transcritical system is better in regions having lower ambient conditions such as near the Black Sea and eastern regions of Turkey. Therefore, for the mild and cold regions of Turkey, the transcritical ejector option is the better alternative due to having higher performance compared to the cascade system.en_US
dc.language.isoengen_US
dc.publisherVINCA INST NUCLEAR SCIen_US
dc.relation.ispartofTHERMAL SCIENCEen_US
dc.identifier.doi10.2298/TSCI180911348Yen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectNatural Refrigerantsen_US
dc.subjectTranscritical Ejector Systemen_US
dc.subjectCascade Systemen_US
dc.subjectEnergy Efficiency Ratioen_US
dc.titleTHE PERFORMANCE EVALUATION OF R744 TRANSCRITICAL EJECTOR AND R290/R744 CASCADE REFRIGERATION SYSTEMS FOR TURKEYen_US
dc.typearticleen_US
dc.departmentMühendislik ve Mimarlık Fakültesi, Makina Mühendisliği Bölümüen_US
dc.authorid0000-0003-1109-6397en_US
dc.identifier.volume23en_US
dc.identifier.issue6en_US
dc.identifier.startpage4031en_US
dc.identifier.endpage4041en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.institutionauthorYilmaz, Deniz
dc.authorwosidAAZ-2281-2020en_US
dc.authorscopusid57203156898en_US
dc.identifier.wosqualityQ3en_US
dc.identifier.wosWOS:000519751700034en_US
dc.identifier.scopus2.0-85083981206en_US


Bu öğenin dosyaları: